Comparative analysis of white-to-white and angle-to-angle distance measurements with partial coherence interferometry
Gabor Nemeth1, Ziad Hassan, Eszter Szalai
1Department of Ophthalmology, University of Debrecen, Debrecen, Hungary. nemeth222@yahoo.com
Purpose:
To perform white-to-white (WTW) and angle-to-angle (ATA) distance measurements with 2 optical devices and analyze the correlation with other anterior segment parameters.
Setting:
Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary.
Design:
Comparative case series.
Methods:
In this prospective study, the WTW distance, axial length (AL), and anterior chamber depth (ACD) were measured by partial coherence interferometry (PCI) (IOLMaster). The horizontal and vertical ATA distances and ACD were assessed by anterior segment optical coherence tomography (AS-OCT) (Visante).
Results:
The mean PCI values were AL, 23.31 mm ± 1.52 (SD); WTW distance, 11.99 ± 0.47 mm; ACD, 2.99 ± 0.4 mm. On AS-OCT, the mean horizontal ATA was 11.43 ± 0.51 mm and the mean vertical ATA, 10.72 ± 0.66 mm. The WTW distance was significantly greater than the horizontal ATA distance, and the horizontal ATA distance was significantly greater than the vertical ATA distance (P<.0001). The correlations between WTW and horizontal ATA (r = 0.51; P<.0001), vertical ATA (r = 0.32; P<.0021), AL (r = 0.45; P<.0001), and patient age (r = -0.28; P = .023) were significant. The PCI WTW distance and ACD were significantly correlated (r = 0.55; P<.0001). There were no significant correlations between AS-OCT horizontal and vertical ATA measurements (r = -0.02; P = 0.79) or between same-device ACD measurements (r = 0.18; P = .15).
Conclusions:
Although PCI WTW and AS-OCT ATA measurements are not clinically interchangeable, the WTW values correlated well with horizontal and vertical measurements and other anterior segment parameters.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...