pH transients in hydroxyapatite chromatography columns-Effects of operating conditions and media properties
Laura Dattolo1, Emily L Keller, Giorgio Carta
1Department of Chemical Engineering, University of Virginia, 102 Engineers' Way, Charlottesville, VA 22904-4741, USA.
Abstract:
pH transitions occur in hydroxyapatite (HAP) columns that are subject to step changes in salt concentration, which have been shown to be controlled by proton exchange on the HAP surface. The pH temporarily decreases before gradually returning to the feed value when the salt concentration increases, potentially compromising the stability of the HAP when either the magnitude or duration of the pH drop is excessive. The opposite happens when the salt concentration decreases. In this work we address the effects of several key variables: the flow rate, the particle size, the use of salt gradients instead of steps, the use of different co-buffers, the surface area of the HAP, and the use of a slightly alkaline wash prior to increasing the salt concentration. Flow rate and particle size were found to have virtually no effect, demonstrating that the pH transitions are equilibrium rather than kinetically driven. Salt gradients resulted in smaller pH drops compared to steps since the exchanged protons are diluted over the gradient volume. MES and histidine used as co-buffers were effective at reducing the duration of the pH transitions but did not affect their magnitude. The same result was found when comparing HAP samples with different surface areas, with the lower surface area HAP yielding much shorter duration but similar pH drops and rises. Finally, washing the HAP column with a pH 7.5 buffer prior to the salt step was found to dramatically reduce the subsequent pH drop. In general, there was good agreement between these results and predictions based on our previously developed model.
Related Concept Videos
Ion-Exchange Chromatography
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...