A tangentially viewing fast ion D-alpha diagnostic for NSTX
A Bortolon1, W W Heidbrink, M Podestà
1University of California, Irvine, California 92697, USA. abortolo@pppl.gov
The Review of Scientific Instruments
|November 2, 2010
Summary
A new Fast Ion D-alpha (FIDA) diagnostic system will enhance NSTX
Area of Science:
- Plasma physics
- Fusion energy research
- Diagnostic techniques
Background:
- NSTX currently utilizes perpendicular viewing FIDA diagnostics.
- Enhancing diagnostic capabilities is crucial for understanding fast ion behavior in fusion plasmas.
Purpose of the Study:
- To introduce a second Fast Ion D-alpha (FIDA) installation at NSTX.
- To complement existing FIDA diagnostics with tangential viewing.
- To improve velocity-space resolution for detailed fast ion analysis.
Main Methods:
- Installation of two new FIDA instruments with tangential viewing.
- Spectroscopic diagnostic for fast ion spectra and profiles (16 radial points, 5-10 ms resolution).
- Photomultiplier system for FIDA light change measurements (50 kHz sampling rate).
Main Results:
- Minimized spectral contamination due to tangential viewing geometry.
- Enhanced capability to measure fast ion behavior.
- Improved velocity-space resolution for detailed plasma diagnostics.
Conclusions:
- The new FIDA system will provide crucial data on neutral-beam current drive.
- It will offer insights into fast ion acceleration and transport by RF waves and instabilities.
- This advancement supports the understanding of plasma dynamics in fusion devices.
Related Concept Videos
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Nuclear Overhauser Enhancement (NOE)
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.