Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Machine learning based spectral fitting and atomic physics corrections for the main ion charge exchange recombination
S R Haskey1, B Grierson2, S K Kim1
1Princeton Plasma Physics Laboratory, P.O. Box 451, Princeton, New Jersey 08543, USA.
Abstract:
Rapid and accurate machine learning (ML) based analysis of the Doppler broadened and shifted Balmer-α spectra from the main ion charge exchange recombination spectroscopy (MICER) diagnostic on the DIII-D tokamak has been developed to provide raw measurements of the main ion (typically D+) temperature, toroidal rotation, density, and beam emission based measurements directly from the active Balmer-α spectra. The temperatures and toroidal rotations are typically within 150 eV and 10 km/s of those obtained from the standard least squares fitting approach. The raw measurements are then corrected for systematic errors using a second set of ML models that were trained as inverse surrogates for the FIDASIM three dimensional collisional radiative model. FIDASIM provides a comprehensive forward model of the raw measurements, including atomic physics and spatial smearing effects. At the pedestal top, corrections to the ion temperature are typically 150 eV but can be up to 300 eV. The standard deviation of the difference between the surrogate and the full model based correction is less than 50 eV, with some of this difference due to Monte Carlo noise from the FIDASIM model. 20 000 FIDASIM simulations spanning the relevant DIII-D parameter space were used for the training and validation of the ML model, incorporating variations in ion and electron profiles, as well as variations in the neutral beam injector parameters and magnetic equilibrium mapping. The complexity of the MICER spectra and associated corrections has historically limited analysis to high priority discharges, despite the wealth of information contained in the spectra. These advances have dramatically reduced the analysis time for single discharges from several hours to seconds. The speed-up now allows bulk analysis of thousands of historical discharges acquired by the diagnostic during its 12+ years of operation on DIII-D, enabling a variety of studies, such as those involving H-mode main ion pedestal profiles.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
06:46Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Instrumentation
Mass Spectrum: Interpretation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.