Related Experiment Video
Updated: Jun 7, 2026

Purification of the Cystic Fibrosis Transmembrane Conductance Regulator Protein Expressed in Saccharomyces cerevisiae
Published on: May 10, 2014
First certified reference material for cystatin C in human serum ERM-DA471/IFCC
Anders Grubb1, Søren Blirup-Jensen, Veronica Lindström
1Department of Clinical Chemistry, University Hospital, Lund, Sweden.
A new certified reference material for Cystatin C (ERM-DA471/IFCC) is now available. This material, standardized by the IFCC Working Group for the Standardisation of Cystatin C, ensures accurate measurement of Cystatin C levels.
Area of Science:
- Clinical Chemistry
- Biochemistry
- Reference Materials
Background:
- Accurate measurement of Cystatin C is crucial for assessing kidney function.
- Standardization of Cystatin C assays is needed to ensure reliable results across different laboratories.
- The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group for the Standardisation of Cystatin C (WG-SCC) addresses this need.
Purpose of the Study:
- To announce the availability of a new certified reference material for Cystatin C (ERM-DA471/IFCC).
- To provide a standardized material for the accurate quantification of Cystatin C.
- To support the harmonization of Cystatin C measurements in clinical laboratories.
Main Methods:
- Development and characterization of a pure protein primary reference preparation (PRP) from recombinant Cystatin C.
- Determination of PRP concentration using dry mass measurement.
- Characterization of the certified reference material ERM-DA471/IFCC using particle enhanced immuno-nephelometry, particle enhanced immuno-turbidimetry, and enzyme amplified single radial immuno-diffusion.
Main Results:
- The certified Cystatin C mass concentration in ERM-DA471/IFCC is 5.48 mg/L.
- The expanded uncertainty (k=2) for the certified value is 0.15 mg/L.
- The material was characterized using a primary reference preparation calibrated by dry mass determination.
Conclusions:
- The new certified reference material ERM-DA471/IFCC provides a reliable standard for Cystatin C measurement.
- This material will aid in the standardization and harmonization of Cystatin C assays.
- Availability of ERM-DA471/IFCC supports improved clinical assessment of kidney function through accurate Cystatin C quantification.