Related Experiment Video
Updated: Jun 6, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Human body area factors for radiation exchange analysis: standing and walking postures
Sookuk Park1, Stanton E Tuller
1Climate Laboratory, Department of Geography, University of Victoria, BC, Canada. sooland@gmail.com
Abstract:
Effective radiation area factors (f (eff)) and projected area factors (f (p)) of unclothed Caucasians' standing and walking postures used in estimating human radiation exchange with the surrounding environment were determined from a sample of adults in Canada. Several three-dimensional (3D) computer body models were created for standing and walking postures. Only small differences in f (eff) and f (p) values for standing posture were found between gender (male or female) and body type (normal- or over-weight). Differences between this study and previous studies were much larger: ≤0.173 in f (p) and ≤0.101 in f (eff). Directionless f (p) values for walking posture also had only minor differences between genders and positions in a stride. However, the differences of mean directional f (p) values of the positions dependent on azimuth angles were large enough, ≤0.072, to create important differences in modeled radiation receipt. Differences in f (eff) values were small: 0.02 between the normal-weight male and female models and up to 0.033 between positions in a stride. Variations of directional f (p) values depending on solar altitudes for walking posture were narrower than those for standing posture. When both standing and walking postures are considered, the mean f (eff) value, 0.836, of standing (0.826) and walking (0.846) could be used. However, f (p) values should be selected carefully because differences between directional and directionless f (p) values were large enough that they could influence the estimated level of human thermal sensation.
More Related Videos
08:24Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Absorption of Radiation
Factors Affecting Respiration
Factors Affecting Body Temperature
Factors may include: