Related Experiment Video
Updated: Jun 6, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Comparative evaluation of software for retention time alignment of gas chromatography/time-of-flight mass
Yueting Koh1, Kishore Kumar Pasikanti, Chun Wei Yap
1Department of Pharmacy, Faculty of Science, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore.
Abstract:
In chromatography-based metabonomic research, retention time (RT) alignment of chromatographic peaks poses a challenge for the accurate profiling of biomarkers. Although a number of RT alignment software has been reported, the performance of these software packages have not been comprehensively evaluated. This study aimed to evaluate the RT alignment accuracy of publicly available and commercial RT alignment software. Two gas chromatography/mass spectrometry (GC/MS) datasets acquired from a mixture of standard metabolites and human bladder cancer urine samples, were used to assess three publicly available software packages, MetAlign, MZmine and TagFinder, and two commercial applications comprising the Calibration feature and Statistical Compare of ChromaTOF software. The overall RT alignment accuracies in aligning standard compounds mixture were 93, 92, 74, 73 and 42% for Calibration feature, MZmine, MetAlign, Statistical Compare and TagFinder, respectively. Additionally, unique trends were observed for the individual software with regards to the different experimental conditions related to extent and direction of RT shifts. Conflicting performance was observed for human urine samples suggesting that RT misalignments still occurred despite the use of RT alignment software. While RT alignment remains an inevitable step in data preprocessing, metabonomic researchers are recommended to perform manual check on the RT alignment of important biomarkers as part of their validation process.
More Related Videos
08:232 in 1: One-step Affinity Purification for the Parallel Analysis of Protein-Protein and Protein-Metabolite Complexes
Published on: August 6, 2018
08:07Sample Preparation for Single Cell Mass Spectrometry Metabolomics Studies: Combined Cell Washing, Quenching, Drying, and Storage
Published on: September 16, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry