Related Experiment Video
Updated: Jun 6, 2026

05:00
Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
1995 Atmospheric Trace Molecule Spectroscopy (ATMOS) linelist
Applied Optics
|November 19, 2010
Summary
The Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment created an updated molecular database for analyzing atmospheric spectra. This database includes line parameters for 49 molecules, enhancing atmospheric research.
Area of Science:
- Atmospheric science
- Spectroscopy
- Planetary science
Background:
- The Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment utilizes infrared solar occultation spectroscopy.
- Accurate molecular spectroscopic data is crucial for analyzing atmospheric composition from space-based measurements.
- Previous versions of the ATMOS database have been instrumental in atmospheric research.
Purpose of the Study:
- To describe the current molecular spectroscopic database used for analyzing ATMOS data.
- To provide an updated compilation of line parameters for 49 molecular species.
- To detail the structure and content of the ATMOS database, including differences from other compilations.
Main Methods:
- Utilizing a Fourier-transform spectrometer on the Space Shuttle to record atmospheric spectra.
- Developing and maintaining an extended molecular spectroscopic database.
- Compiling line parameters for 49 molecular species across a wide spectral range (0-10000 cm(-1)).
Main Results:
- The ATMOS database is a three-part compilation including a main list of nearly 700,000 entries, updated from HITRAN 1992.
- Supplemental line parameters and absorption cross-sections for heavy molecules are included.
- The database covers spectral information for 49 molecular species relevant to atmospheric studies.
Conclusions:
- The described ATMOS database provides a comprehensive resource for the analysis of infrared solar occultation spectra.
- This updated database enhances the accuracy of atmospheric trace molecule identification and quantification.
- The work facilitates further research in atmospheric science and remote sensing.
More Related Videos
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Instrumentation
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.

