Related Experiment Video
Updated: Jun 6, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Reduced confounding by impaired ventilatory function with oxygen uptake efficiency slope and VE/VCO2 slope rather
Anthony J Barron1, Katharine I Medlow, Alberto Giannoni
1International Centre for Circulatory Health, Imperial College London and Imperial College NHS Trust, London, UK. anthonybarron@hotmail.co.uk
Abstract:
Heart failure and ventilatory disease often coexist; both create abnormalities in cardiopulmonary exercise test measurements. The authors evaluated the relative dependency of a well-recognized index of heart failure, peak oxygen consumption (VO(2)), and 2 newer indices, the minute ventilation (VE)/carbon dioxide production (VCO(2)) slope and oxygen uptake efficiency slope (OUES), on standard markers of impaired cardiac and ventilatory function. One hundred twenty-four patients (median age, 65.8; range, 22.6-84.9), with functional limitation from clinical heart failure were exercised. Peak VO(2) was 17.14 ± 7.58 mL/kg/min, VE/VCO(2) slope 50.1 ± 20.1, OUES 1.46 ± 0.68 L/min, and forced expiratory volume in 1 second (FEV(1) ) 1.88 ± 0.75 L. Peak VO(2) is substantially more sensitive to FEV(1) than ejection fraction (4.0 mL/kg/min difference between above- and below-median FEV(1) and 1.5 mL/kg/min between above- and below-median ejection fraction). OUES does not share this peculiar excess sensitivity to FEV(1) (0.12 L/min difference between above- and below-median FEV(1) and 0.01 L/min between above- and below-median ejection fraction). VE/VCO(2) slope has a borderline effect by FEV(1) (7.07 difference between above- and below-median FEV(1) and 2.07 between above- and below-median ejection fraction). Although widely used as a marker of heart failure severity, peak VO(2) is very sensitive to spirometry status and is indeed more affected by FEV(1) than by ejection fraction. OUES in contrast does not show this preferential sensitivity to impaired FEV(1).
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...