Related Experiment Video
Updated: Jun 6, 2026

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Management of a failed mandibular staple implant: a clinical report
Ronald L Ettinger1, Ali Fakhry
1Department of Prosthodontics and Dows Institute for Dental Research, University of Iowa, Iowa City, Iowa 52242, USA. ronald-ettinger@uiowa.edu
Abstract:
A 48-year-old woman sought treatment because her staple implant-retained overdenture was no longer retentive, and the denture was worn over the abutments. After unsuccessfully attempting to move the retentive nuts along the transosseous posts of the staple implant, the posts were cut off at the level of the bone. Two endosseous implants were placed around the staple implant, and a new implant-retained overdenture was fabricated and inserted using ball attachments for retention. This article describes the treatment for this patient, who has been wearing the new dentures successfully for the past 4 years.