Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Validity of a new method to estimate mean arterial pressure at brachial level
Sebastian Graf1, Damian Craiem, Ricardo L Armentano
1Favaloro University, Av. Belgrano 1723 (1093), Buenos Aires, Argentina. graf@favaloro.edu.ar
Abstract:
The value of mean arterial pressure (MBP) is of clinical importance, and is required for peripheral resistance calculation as well as for central blood pressure calibration procedures. MBP is usually estimated at the upper arm using systolic and diastolic sphygmomanometers pressure values, as 33% of pulse pressure (PP) above diastolic pressure. In a previous work, we proposed to use 38%. The aim of this study was to investigate the validity of the proposed formula to calculate MBP, when assessing subjects with a wide range of blood pressure and pulse wave velocity (PWV) levels. In 73 volunteers (56 ± 10 years, range: 27-82; pulse pressure: 59 ± 12 mmHg, range: 43-86; PWV: 10 ± 2 m/s, range: 8-17) arterial pressure waveforms were obtained at the left brachial artery by applanation tonometry. Diastolic (DBP) and systolic (SBP) brachial pressure were obtained with oscillometric device. Brachial-radial PWV was obtained at the same arm using mechano-transducers. MBP computed as 38% of PP above diastolic pressure, introduces an error of only 0.1% in brachial MBP estimation, independent of pressure and PWV levels.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.