Related Experiment Video
Updated: Jun 6, 2026

A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
Published on: November 13, 2016
Combining EMD with ICA for extracting independent sources from single channel and two-channel data
Bogdan Mijovic1, Maarten De Vos, Ivan Gligorijevic
1Department of Electrical Engineering (ESAT), division SCD, Katholieke Universiteit Leuven, 3001, Belgium. bogdan.mijovic@esat.kuleuven.be
Abstract:
Blind Source Separation (BSS) techniques are frequently needed in the processing of biomedical signals. This need comes from the fact that these signals are often composed of many different sources, which are mixed in the measured signal. However, we are usually only interested in examining one or a limited set of sources of interest separately. A variety of algorithms exist for separating multichannel mixtures into its independent sources (e.g. different Independent Component Analysis (ICA) techniques). These techniques only work if the number of channels is larger than, or equal to the number of sources present in the signal. On the other hand, only a few algorithms have been reported for the analysis of single channel sources, or other mixtures where the number of sources is higher than the number of channels. In this work we show a new technique which combines Empirical Mode Decomposition (EMD) and Independent Component Analysis (ICA). We will show that this technique is capable in separating independent sources when the number of these sources is higher than the number of channels available. We show the performance in single channel and two-channel biosignal processing.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Ion-Exchange Chromatography
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...