Related Experiment Video
Updated: Jun 6, 2026

Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
Thermal parameters measurement on fire fighter: improvement of the monitoring system
A Oliveira1, C Gehin, B Massot
1Biomedical Sensors Group, Université de Lyon; Institut des Nanotechnologies de Lyon INL-UMR5270, CNRS, INSA de Lyon, Villeurbanne, F-69621, France. aurelien.oliveira@insa-lyon.fr
Abstract:
Real time monitoring of the thermal parameters on firefighter when operating is one of the ProeTEX project goals. The newly developed equipments in the framework of this project, integrate one temperature sensor and one heat flux sensor in the rescuer's outer garment. The environment in which firefighters operate is dangerous and the thermal risks can occur everywhere. Consequently the heat flux is so not necessarily symmetrical. To improve the thermally at risk situation detection, a modified platinum sensors array was integrated in the jacket in order to monitor simultaneously heat flux and temperature surrounding the rescuer. The sensors were placed in the most exposed area (shoulders and chest) to monitor thermal parameter in different directions. The heat flux is calculated from the temperature difference. This sensors array enables the detection of temperature increases and heat flux even when the heat source is localized on one side.
Related Concept Videos
Flame Photometry: Overview
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...