Related Experiment Video
Updated: Jun 6, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Classification of low systemic vascular resistance using photoplethysmogram and routine cardiovascular measurements
Qim Y Lee1, Gregory S H Chan, Stephen J Redmond
1Biomedical Systems Laboratory, School of Electrical Engineering and Telecommunications, the University of New South Wales, Sydney, 2052, Australia.
Abstract:
Low systemic vascular resistance (SVR) can be a useful indicator for early diagnosis of critical pathophysiological conditions such as sepsis, and the ability to identify low SVR from simple and noninvasive physiological signals is of immense clinical value. In this study, an SVR classification system is presented to recognize the occurrence of low SVR, among a heterogenous group of patients (N = 48), based on the use of routine cardiovascular measurements and features extracted from the finger photoplethysmogram (PPG) as inputs to a quadratic discriminant classifier. An exhaustive feature search was performed to identify a near optimum feature subset. Cohen's kappa coefficient (κ) was used as a performance measure to compare candidate feature sets. The classifier using the following combination of features performed best (κ = 0.56, sensitivity = 96.30%, positive predictivity = 92.31%): normalized low-frequency power (LFNU) derived from PPG, ratio of low-frequency power to high-frequency power (LF/HF) of the PPG variability signal, and the ratio of mean arterial pressure to heart rate (MAP/HR). Classifiers that used either LF(NU) (κ = 0.43), LF/HF (κ = 0.37) or MAP/HR (κ = 0.43) alone showed inferior performance. Discrimination of patients with and without low SVR can be achieved with reasonable accuracy using multiple features derived from the PPG combined with routine cardiovascular measurements.
Related Concept Videos
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...

