Related Experiment Video
Updated: Jun 6, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Comparison of volatile components in Chinese traditional pickled peppers using HS-SPME-GC-MS, GC-O and multivariate
1Department of Perfume and Aroma Technology, Shanghai Institute of Technology, China. xzb@sit.edu.cn
Abstract:
Volatile compounds of Chinese traditional pickled peppers (CTPPs) were extracted by solid-phase micro-extraction (SPME) and analysed by gas chromatography-mass spectrometry (GC-MS) and gas chromatography-olfactometry (GC-O) to visually compare their volatile compositions by applying principal component analysis (PCA). A total of 67 volatile components were identified by GC-MS, including 7 acids, 6 alkanes, 14 alcohols, 9 esters, 11 terpenes, 3 aldehydes, 5 ketones, 7 phenols and 5 miscellaneous compounds, tentatively identified or identified by comparing with mass spectra and retention indices of the standards or from literature. Of 45 volatile compounds detected in the sniffing port of GC-O, the majority of odour-active components included acetic acid, 2-ethyl phenol, L-linalool, tridecane, butyl butanoate, δ-3-carene. The individual concentrations of the volatile compounds such as acetic acid, ethanol, 1-propanol, L-linalool, hexyl 2-methyl butyrate and hexyl pentanoate corresponded well to the intensities of related attributes in the correlation analysis. Due to their high concentration level and low threshold value, these compounds played an important role in the final aromatic profile of the pickled peppers. The differences in flavours were observed by applying PCA to GC-MS data sets. From the PCA results, samples were primarily separated along the first principal component.
More Related Videos
07:502D-HPLC-MS Technology Combined with Molecular Network for the Identification of Components in Tibetan Medicine Aconitum pendulum
Published on: December 8, 2023
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Volatilization