Related Experiment Videos
Active sound transmission control of a double-panel module using decoupled analog feedback control: experimental
Jason D Sagers1, Timothy W Leishman, Jonathan D Blotter
1Applied Research Laboratories, The University of Texas at Austin, Texas 78758, USA.
Abstract:
Low-frequency sound transmission through passive lightweight partitions often renders them ineffective as means of sound isolation. As a result, researchers have investigated actively controlled lightweight partitions in an effort to remedy this problem. One promising approach involves active segmented partitions (ASPs), in which partitions are segmented into several distinctly controlled modules. This paper provides an experimental analysis of a double-panel ASP module wherein the source- and transmitting-side panels are independently controlled by an analog feedback controller. Experimental results, including plant frequency response functions, acoustic coupling strengths, frequency response functions, and transmission losses (TLs) of single- and double-panel modules, are presented and compared to numerical predictions. Over the bandwidth of 20 Hz to 1 kHz, the average measured TL for an actively controlled single-panel module was 29 dB, compared to 14 dB for the passive case. The average measured TL over the same bandwidth for the actively controlled double-panel module was 57 dB, compared to 31 dB for the passive case.
Related Concept Videos
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal and...
Design Example
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...