Related Experiment Video
Updated: Jun 6, 2026

An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
Blood temperature management and gaseous microemboli creation: an in-vitro analysis
Joseph Sleep1, Ingrid Syhre, Ed Evans
1Midwestern University, Cardiovascular Science Department, Glendale, Arizona 85308, USA. jr_sleep@yahoo.com
Abstract:
Gaseous microemboli have been associated with post operative neurological deficits in patients undergoing cardiopulmonary bypass. Creating an optimal perfusion system that minimizes microemboli production and has enhanced abilities to sequester entrained air during the bypass procedure has been an important focus. This study examines the air-handling capabilities of a cardiopulmonary bypass circuit and correlates blood temperatures with microemboli loads proximal and distal to the arterial line filter within the circuit. Utilizing a Capiox RX25R oxygenator, Capiox 37 micron arterial filter, vacuum assisted venous return, and emboli detectors, 30 mL of air were injected into the venous line of a bypass circuit at eight different temperatures. Emboli were counted distal to the arterial line filter by the EDAQ Quantifier (Emboli Detection and Classification). The average number of emboli detected distal to the arterial filter progressively increased as the perfusate temperature was dropped. At 37.0 degrees C an average of 1.4 emboli was observed distal to the arterial filter within 90 seconds of the air injection. At 23.0 degrees C an average of 49.8 emboli was detected. Air introduced into the venous side of the bypass circuit resulted in showers of microemboli being sent past the arterial line filter. In addition, as the bovine blood was cooled, the air handling capability of the circuit was diminished.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

