Electrocardiogram (ECG) interpretation for arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) shows significant variability. Only right precordial T-wave inversion and right bundle branch block (RBBB) are consistently detected, regardless of ECG resolution.
Area of Science:
- Cardiology
- Medical Imaging
- Diagnostic Tools
Background:
- Standardized definitions for arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) electrocardiogram (ECG) features have not resolved prevalence estimate variations.
- This variability necessitates an examination of interpretation consistency across readers and ECG resolutions.
Purpose of the Study:
- To assess the variability in ECG interpretation for ARVD/C among different readers and across various ECG resolutions.
- To determine the reliability of specific ECG parameters in diagnosing ARVD/C.
Main Methods:
- Two blinded readers evaluated quantitative and qualitative ECG features from 20 individuals (10 with ARVD/C).
- ECGs were recorded at standard-speed (SS) and double-speed-double-amplitude (DS) settings, with SS ECGs magnified and analyzed electronically (EL).
- Intraclass correlation coefficients (ICC) and kappa statistics were used to measure intra- and interreader agreement.
Main Results:
- Interreader agreement for QRS duration measurement was moderate (ICC 0.50-0.75) across resolutions.
- Intrareader agreement was good to excellent for QRS duration across all resolutions (ICC 0.60-0.85).
- Consistent agreement was observed only for right precordial T-wave inversion (κ=1) and right bundle branch block morphology (RBBB) (κ=0.83).
Conclusions:
- Right precordial T-wave inversion and RBBB are the most reliable ECG markers for ARVD/C, detectable even with standard ECG resolution.
- Variability in the interpretation of other ECG parameters persists, even with enhanced resolutions, impacting ARVD/C diagnosis.
Introduction:
Despite the use of standardized definitions, widely varying prevalence estimates of electrocardiographic (ECG) features related to arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) have been reported in different cohorts. This study was aimed at examining the variability in the ECG interpretation resulting from the same reader, different readers, and using different ECG-resolutions.
Methods And Results:
Blinded to other clinical data, 2 readers examined quantitative and qualitative ECG features of 20 (10 ARVD/C) randomly selected individuals. ECGs were recorded at standard-speed (SS) and double-speed-double-amplitude (DS) settings. The SS ECGs were scanned, magnified 4×, and evaluated using electronic calipers (EL). One reader repeated all measurements. For both readers, the intraclass correlation coefficient (ICC) for the measurement of QRS duration was good between conventional and electronic evaluation [DS vs EL: Reader 1--0.64 (0.52-0.73); Reader 2--0.67 (0.55-0.76)][SS vs EL: Reader 1--0.60 (0.47-0.70); Reader 2--0.60 (0.47-0.70)]. Using the same resolution, the intrareader ICC was good for SS [0.70 (0.59-0.78)], DS [0.85 (0.80-0.90)], and EL [0.70 (0.69-0.83)] resolutions, but deteriorated for interreader comparisons [0.50 (0.36-0.62), 0.75 (0.66-0.82), and 0.75 (0.66-0.82), respectively]. For qualitative parameters, the intra- and interreader agreement was inconsistent for all but 2 parameters. Both readers were in perfect agreement while interpreting right precordial T-wave inversion [κ= 1] and right bundle branch block morphology (RBBB) [κ= 0.83 (0.5-1.0)] even when using SS resolution.
Conclusions:
Right precordial t-wave inversion and RBBB are the only ECG parameters that can be detected consistently even using the conventionally used ECG-resolution. The substantial variability in evaluation of other parameters is not improved even with the use of higher resolutions.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Cardiomyopathy IV: Restrictive Cardiomyopathy
Mechanism of Cardiac Arrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...