Related Experiment Video
Updated: Jun 6, 2026

10:10
Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Scapular notching in reverse shoulder arthroplasty: is it important to avoid it and how?
Christophe Lévigne1, Jérome Garret, Pascal Boileau
1Clinique du parc, 155 ter Bd Stalingrad, 69006 Lyon, France. c.levigne@cliniqueduparclyon.fr
Clinical Orthopaedics and Related Research
|December 1, 2010
Summary
Scapular notching is common after reverse shoulder arthroplasty (RSA), often progressing and linked to poorer outcomes. Preoperative glenoid erosion influences notching, emphasizing careful implant positioning to avoid complications.
Area of Science:
- Orthopedic surgery
- Radiology
- Biomedical engineering
Background:
- Scapular notching is a radiographic finding specific to reverse shoulder arthroplasty (RSA), characterized by erosion of the scapular neck.
- The clinical and radiological significance of scapular notching remains incompletely understood.
Purpose of the Study:
- To determine the incidence and natural history of scapular notching after RSA.
- To assess the relationship between notching and functional outcomes, radiographic signs of failure, and factors influencing its development.
Main Methods:
- Retrospective review of 448 patients (461 shoulders) who underwent Grammont-type RSA.
- Clinical assessment included Constant-Murley scores and range of motion; radiographic assessment evaluated notching, humeral, and glenoid radiolucent lines.
Main Results:
- Scapular notching occurred in 68% of cases, appearing early with variable progression.
- Notching correlated with follow-up duration, patient strength, shoulder elevation, and the presence of humeral and glenoid radiolucent lines.
- Preoperative superior glenoid erosion was associated with a higher incidence of notching.
Conclusions:
- Scapular notching is a frequent complication of RSA that generally progresses.
- Notching is associated with deterioration in clinical parameters and increased radiolucent lines, suggesting potential implant loosening or failure.
- Preoperative glenoid erosion patterns are critical, influencing surgical technique and implant positioning to mitigate notching risk.