Related Experiment Video
Updated: Jun 6, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial
Raúl Alcaraz1, Fernando Hornero, José J Rieta
1Innovation in Bioengineering Research Group, University of Castilla La Mancha, Campus Universitario, Cuenca, Spain. raul.alcaraz@uclm.es
Abstract:
The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V(1) reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

