Related Experiment Video
Updated: Jun 6, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Long-term results of transpedicle body augmenter in treating burst fractures
Allen Li1, Jung-Kuei Chen, Kung-Chia Li
1Department of Biology, Johns Hopkins University, Baltimore, MD 21218, USA.
Background:
Short-segment fixation alone to treat thoracolumbar burst fractures is common but it has a 20-50% incidence of implant failure and rekyphosis. A transpedicle body augmenter (TpBA) to reinforce the vertebral body via posterior approach has been reported to prevent implant failure and increase the clinical success rate in treating burst fracture. This article is to evaluate the longterm results of short-segment fixation with TpBA for treatment of thoracolumbar burst fractures.
Materials And Methods:
Patients included in the study had a single-level burst fracture involving T11-L2 and no distraction or rotation element with limited neurological deficit. Patients in the control group (n = 42) were treated with short-segment posterior instrumentation alone, whereas patients in the augmented group (n = 90) were treated with a titanium spacer designed for transpedicle body reconstruction. The followup was 48-101 months. The radiographic and clinical results were evaluated and compared by Student's t test and Fisher's exact test.
Results:
The blood loss, operation time and hospitalization were similar in both the groups. The immediate postoperative anterior vertebral restoration rate of the augmented group was similar to that of the control group (97.6% ± 2.4% vs. 96.6% ± 3.2%). The final anterior vertebral restoration was greater in the augmented group than in the control group (93.3% ± 3.4% vs. 62.5% ± 11.2%). Immediate postoperative kyphotic angles were not significantly different between the groups (3.0° ± 1.8° vs. 5.1° ± 2.3°). The final kyphotic angles were less in the augmented group than the control group (7.3° ± 3.5° vs. 20.1° ± 5.4°). The augmented group had less (P < 0.001) implant failure [0% (n=0) vs. 23.8% (n=10)] for the control group) and more patients (P < 0.001) with no pain or minimal or occasional pain (Grade P1 or P2) than the control group [90.0% (n=81) vs. 66.7% (n=28)]. All patients in the augmented group and 39 (92.8%) patients in the control group experienced neurological recovery to Frankel Grade E. Three patients in the control group had improvement to Frankel Grade D from Frankel Grade C, but later had deterioration to Frankel Grade C because of loosening and dislodgement of the implant.
Conclusion:
Posterior body reconstruction with TpBA can maintain kyphosis correction and vertebral restoration, prevent implant failure and lead to better clinical results.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...