Related Experiment Video
Updated: Jun 6, 2026

Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
Toluidine blue adsorbed on alcohol dehydrogenase modified glassy carbon electrode for voltammetric determination of
Arun Prakash Periasamy1, Yogeswaran Umasankar, Shen-Ming Chen
1Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan, ROC.
Abstract:
A novel toluidine blue O (TBO) adsorbed alcohol dehydrogenase (ADH) biocomposite film have been prepared through simple adsorption technique with the help of electrostatic interaction between oppositely charged layers. Nafion (NF) coating was made on top of the biocomposite film modified glassy carbon electrode (GCE) to protect ADH from leaching. The fabricated ADH/TBO/NF biocomposite electrode remains highly stable in the pH range from 4 to 13. More facile electron transfer process occurs at ADH/TBO/NF biocomposite than at TBO/NF film, which is obvious from the six folds increase in k(s) value. Maximum surface coverage concentration (Γ) of TBO is noticed at ADH/TBO/NF film, which is 82% higher than at TBO/NF and 15% higher than at ADH/TBO film modified GCEs. Electrochemical impedance spectroscopy studies reveal that ADH has been well immobilized in the biocomposite film. Scanning electron microscopy studies confirm the discriminate surface morphology of various components present in the biocomposite film. Cyclic voltammetry studies validate that ADH/TBO/NF biocomposite film exhibits excellent electrocatalytic activity for ethanol oxidation at low over potential (I(pa)=-0.14 V). The same studies show biocomposite film possesses a good sensitivity of 7.91 μAM(-1)cm(-2) for ethanol determination. This above sensitivity value is 17.40% higher than the sensitivity obtained for TBO/NF film (6.74 μAM(-1)cm(-2)). Further, using differential pulse voltammetry, a sensitivity of 1.70 μAM(-1)cm(-2) has been achieved for ADH/TBO/NF biocomposite film.
More Related Videos
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Amperometry: Overview
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Potentiometry: Membrane Electrodes

