Related Experiment Video
Updated: Jun 6, 2026

Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
[Blood rheology analysis of 23436 samples and establishment of reference range by sitting and lying position]
Su-zhen Li1, Jun-bing Liang, Jin-xiu Fan
1Department of Clinical Laboratary,Taizhou Central Hospital, Taizhou 318000, China.
Aim:
To establish reference range of blood theology for different gender by sitting and lying in healthy populations.
Methods:
In 31 volunteers blood were drawed in the postures of sitting and lying to measure blood rheology. Data (between July 2002 and July 2006) of 32854 samples (23436 check-up, 6553 out-patient,2865 in-patient) were collected. Differences between different postures and different gender were compared by Independ-Sample t-test with SPSS 13.0 software and each reference range of blood rheology was established.
Results:
In sitting and lying postures 12 parameters of blood rheology showed great significance (P < 0.01). 8 parameters such as whole blood viscosity, blood reduce viscosity, plasma viscosity, hematocrit, were decreased by 9.33% on average while posture was changed from sitting to lying. But index of erythrocyte deformability, erythrocyte electrophoresis presented inverse correlation and were increased by 6.49% on average with the same posture change.Various parameters of blood theology in different gender showed great significance (P < 0.01).
Conclusion:
There is significant difference in various parameters of blood rheology in the posture change from sitting to lying. Reference ranges of blood theology of different postures are established which may be used to decrease the rate of misdiagnosis by 8-10 percent.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure in the Leg
Preparation:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: