Related Experiment Video
Updated: Jun 5, 2026

10:10
Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
An aptamer-based chromatographic strip assay for sensitive toxin semi-quantitative detection
Libing Wang1, Wenwei Ma, Wei Chen
1School of Food Science & Technology, State Key Lab of Food Science & Technology, Jiangnan University, Wuxi 214122, China.
Biosensors & Bioelectronics
|December 21, 2010
Summary
A new aptamer-based strip assay offers rapid detection of ochratoxin A toxin. This method is more sensitive and faster than traditional antibody-based strips, enabling quick on-site toxin analysis.
Area of Science:
- Analytical Chemistry
- Biosensing Technology
- Food Safety
Background:
- Ochratoxin A (OA) is a prevalent mycotoxin posing significant health risks.
- Current detection methods for OA can be time-consuming and require laboratory settings.
- Development of rapid, sensitive, and on-site detection tools for OA is crucial.
Purpose of the Study:
- To develop and validate an aptamer-based chromatographic strip assay for the rapid detection of ochratoxin A.
- To compare the sensitivity and efficiency of the aptamer-based strip assay with conventional antibody-based methods.
- To assess the potential of the assay for on-site, real-time toxin screening.
Main Methods:
- A competitive assay format was designed utilizing aptamers that bind to ochratoxin A.
- DNA probes were employed in conjunction with aptamers for signal generation in a strip assay format.
- The assay principle relies on the competition between ochratoxin A and DNA probes for aptamer binding.
- Visual and reader-based detection methods were utilized to determine the limit of detection (LOD).
Main Results:
- The aptamer-based strip assay demonstrated superior sensitivity compared to traditional antibody-based strips.
- A visual limit of detection (LOD) of 1 ng/mL was achieved for qualitative detection.
- Semi-quantitative detection yielded an LOD as low as 0.18 ng/mL when using a scanning reader.
- Recovery rates for test samples ranged effectively from 96% to 110%.
- Assay completion time was less than 10 minutes, highlighting its rapid nature.
Conclusions:
- The developed aptamer-based strip assay is a highly sensitive and rapid method for ochratoxin A detection.
- The assay's speed and on-site applicability make it a valuable tool for food safety monitoring.
- This technology offers a promising alternative to conventional methods for toxin analysis.

