Sustainable oil-in-water analysis using a supercritical fluid carbon dioxide extraction system directly interfaced
Edward D Ramsey1, Qiubai Sun, Zhiqiang Zhang
1School of Chemical Engineering, University of Science and Technology Liaoning, Anshan 114051, China. syphir2008@gmail.com
Abstract:
A direct aqueous supercritical fluid extraction (SFE) system using carbon dioxide provides a sustainable means by which a vast range of industries may continue to depend on well established infrared (IR) techniques to determine oil-in-water. The SFE-IR method provides an environmentally friendly substitute for current national standard IR reference methods for measuring oil-in-water that rely on using increasingly restricted ozone depleting solvents whose manufacture is being phased out in accordance with international law. The SFE-IR analysis of a 500 mL water sample can be accomplished in 15 min. A rapid on-line SFE-IR calibration method has been implemented. With this calibration method, SFE-IR accuracy for determining diesel oil in 500 mL spiked water samples using single wave number measurement was 86.0%-98.8% with precision (RSD) ranging from 2.5%-7.0%. Using a general purpose calculation which involves measuring infrared absorbance values at three different wave numbers, SFE-IR method accuracy for determining diesel oil in 500 mL spiked water samples was 83.7%-92.2% with RSD 1.0%-9.3%. Data is presented that indicates current long established national standard IR reference methods involving three wave number calculations should be reviewed since, without careful consideration, the inclusion of calculated aromatic hydrocarbon species contributions to final oil-in-water concentration values may provide less accurate results.
More Related Videos
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
11:20In Situ Visualization of the Phase Behavior of Oil Samples Under Refinery Process Conditions
Published on: February 21, 2017
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Spectroscopy of Carboxylic Acid Derivatives
In the...