Radiation protection for accompanying person and radiation workers in PET/CT
Mustafa Demir1, Bayram Demir, Haluk Sayman
1Cerrahpasa Medical Faculty, Department of Nuclear Medicine, Istanbul University, Istanbul, Turkey. demirm@istanbul.edu.tr
Abstract:
The purposes of the present study are to measure the total radiation doses for the radiation workers and for the accompanying person to the patients in positron emission tomography (PET)/computed tomography (CT) imaging. Urines samples from the patients were collected at 43, 62, 87, 117, 238, 362 min after the 555-MBq (18)flour-fluorodeoxyglucose ((18)F-FDG) injection and activities were measured. Dose rates were recorded using a Geiger-Muller counter and the total radiation doses were measured with using an electronic personnel dosemeter. According to the results here, 18.4 % of (18)F-FDG was excreted in the urine in 117 min after injection. At 117th min after injection, dose rates were determined as 345, 220, 140, 50 and 15 µSv h(-1), at proposed distances. The radiation doses after 117 min were measured as 3.92 mSv at 0.1 m, 2.11 mSv at 0.25 m and 1.08 mSv at 0.5 m. In conclusion, radiation protection will be sufficient within 2 h after (18)F-FDG injection for PET/CT imaging in daily practice.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
05:18Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
Published on: October 6, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography