Related Experiment Video
Updated: Oct 11, 2026

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
Published on: May 26, 2019
ACPSEM guideline: commissioning and quality assurance of Magnetic Resonance Imaging Linear Accelerators
Luis Munoz1,2, Reza Alinaghi-Zadeh3, Stephen Gibson4
1GenesisCare , Adelaide, SA, Australia. lmunoz@onephysics.com.
Abstract:
MRI-guided radiotherapy introduces unique quality assurance (QA) requirements due to magnetic field effects on dose delivery, imaging-dependent workflows, adaptive planning and system specific considerations. Consistent, vendor agnostic guidance is needed to support safe commissioning, clinical implementation, and ongoing performance monitoring across MRI-Linac platforms. This guideline defines minimum recommended MRI-Linac commissioning and QA practices to support consistent and safe clinical operation across services. It was developed by the MRI-Linac QA sub-group of the Magnetic Resonance Imaging Linac Working Group using an evidence-informed, consensus-based approach. Key international standards, task group reports, vendor documentation, and peer-reviewed literature relevant to the MRI-Linac were reviewed. Candidate QA tests were mapped to clinical risks and system functions, then organized into commissioning and routine QA domains with suggested cadence. Recommendations were refined through iterative working group review, with emphasis on implementation and auditability. The resulting commissioning recommendations are grouped into domains addressing key performance and safety areas for MRI-Linacs. Additionally, a minimum test set is proposed with suggested frequencies and tolerances where supported by evidence. Adoption of this guideline supports harmonized MRI-Linac QA practice, improved reproducibility across sites, and enhanced patient safety. The framework is designed to be implementable across platforms and evolve as MRI-guided radiotherapy workflows, vendor capabilities, and the evidence matures.
More Related Videos
09:55Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
Published on: January 5, 2024
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging