Related Experiment Video
Updated: Jun 5, 2026

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Real-time methods for estimating organic component mass concentrations from aerosol mass spectrometer data
N L Ng1, M R Canagaratna, J L Jimenez
1Aerodyne Research, Inc., Billerica, Massachusetts 01821, United States.
Abstract:
We use results from positive matrix factorization (PMF) analysis of 15 urban aerosol mass spectrometer (AMS) data sets to derive simple methods for estimating major organic aerosol (OA) component concentrations in real time. PMF analysis extracts mass spectral (MS) profiles and mass concentrations for key OA components such as hydrocarbon-like OA (HOA), oxygenated OA (OOA), low-volatility OOA (LV-OOA), semivolatile OOA (SV-OOA), and biomass burning OA (BBOA). The variability in the component MS across all sites is characterized and used to derive standard profiles for real-time estimation of component concentrations. Two methods for obtaining first-order estimates of the HOA and OOA mass concentrations are evaluated. The first approach is the tracer m/z method, in which the HOA and OOA concentrations are estimated from m/z 57 and m/z 44 as follows: HOA ∼ 13.4 × (C(57) - 0.1 × C(44)) and OOA ∼ 6.6 × C(44), where C(i) is the equivalent mass concentration of tracer ion m/z i. The second approach uses a chemical mass balance (CMB) method in which standard HOA and OOA profiles are used as a priori information for calculating their mass concentrations. The HOA and OOA mass concentrations obtained from the first-order estimates are evaluated by comparing with the corresponding PMF results for each site. Both methods reproduce the HOA and OOA concentrations to within ∼30% of the results from detailed PMF analysis at most sites, with the CMB method being slightly better. For hybrid CMB methods, we find that fixing the LV-OOA spectrum and not constraining the other spectra produces the best results.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview
High-Resolution Mass Spectrometry (HRMS)
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Mass Spectrum: Interpretation
Tandem Mass Spectrometry