Electrically evoked compound action potential measures for virtual channels versus physical electrodes
Michelle L Hughes1, Adam M Goulson
1Boys Town National Research Hospital, Omaha, Nebraska 68131, USA. michelle.hughes@boystown.org
Objectives:
The number of distinct pitch percepts for cochlear implant (CI) listeners is somewhat limited by the number of physical electrodes in the array. Newer-generation CIs have the capability to potentially increase this number by stimulating areas of the cochlea between the physical electrodes. Currently, this is achieved by electrically coupling adjacent electrodes or by simultaneously activating two electrodes with independent current sources (i.e., current steering). Presumably, either type of dual-electrode stimulation will generate neural excitation patterns that are intermediate to those generated by either physical electrode alone (henceforth termed virtual channel). However, it is not clear whether virtual-channel stimulation yields neural recruitment patterns with similar shapes and rates of growth as compared with each physical electrode alone. The purpose of this study was to compare basic electrically evoked compound action potential (ECAP) measures for physical electrodes and virtual channels to determine whether properties of the respective excitation patterns were similar.
Design:
Data were collected for 12 adult CI recipients (six Nucleus Freedom CI24RE, two Advanced Bionics HiResolution 90K, and four Advanced Bionics CII). ECAP responses were measured for a set of three adjacent physical electrodes and two corresponding intermediate virtual channels (e.g., physical electrodes 4, 5, and 6 and virtual channels 4 + 5 and 5 + 6) at three positions along the electrode array (basal, middle, and apical). Virtual channels for Nucleus subjects were produced via electrical coupling of adjacent electrode pairs (dual-electrode mode). For Advanced Bionics subjects, virtual channels were produced via simultaneous, in-phase stimulation of adjacent electrode pairs with 50% of the total current delivered to each electrode in the pair. Specific ECAP measures were as follows: (1) threshold and slope of the input/output functions, (2) amplitude for a masker-probe interval of 1500 microsecs (measure of refractory recovery), and (3) relative location of spread of excitation (SOE) functions among virtual channels and adjacent physical electrodes. Measures for virtual channels were compared with those for the flanking physical electrodes using a multivariate analysis of variance.
Results:
There were no statistically significant differences between physical electrodes and virtual channels for ECAP thresholds, slope of the input/output function, or refractory recovery. On average, SOE functions for the virtual channels were spatially located approximately halfway between SOE functions for the adjacent physical electrodes.
Conclusions:
Results from this study suggest that virtual channels produce neural recruitment patterns with properties similar to those elicited by the adjacent physical electrodes.
Related Concept Videos
Action Potentials
Action Potential
Membrane potential in neurons
Neurons typically have a resting membrane potential of about -70 millivolts (mV). When they receive...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...