High temperature and highly selective stationary phases of ionic liquid bonded polysiloxanes for gas chromatography
Xiaojie Sun1, Yuling Zhu, Peng Wang
1Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei 430072, China.
Abstract:
Due to the special performance of "dual nature" and synthetic flexibility, ionic liquids (ILs) have been an attractive research subject of stationary phases for gas chromatography (GC). In this work, a novel ionic liquid (IL) bonded polysiloxane ([PSOMIM][NTf₂]) with anion of bis-trifluoromethanesulfonylimide (NTf₂⁻) was synthesized, and another one with chloride anion ([PSOMIM][Cl]) was also prepared for the purpose of comparison. The thermo-stability of the product was evaluated by thermogravimetric (TG) test and the result indicated that [PSOMIM][NTf₂] did not decompose slightly until 380 °C. Then the solvation behaviors of the ILs were characterized using solvation parameter model. Subsequently, [PSOMIM][NTf₂] and [PSOMIM][Cl] were used as stationary phases to prepare capillary columns for GC, respectively. The column efficiency of [PSOMIM][NTf₂] column was 4776 plates/m (k=3.64 ± 0.08, naphthalene), and that of the other one was 3170 plates/m (k=2.84 ± 0.11, naphthalene). The selectivity of the novel stationary phases for analytes, including Grob reagent, aromatic positional isomers was further evaluated. Furthermore, the chromatograms of n-alkanes and polycyclic aromatic hydrocarbons (PAHs) on [PSOMIM][NTf₂] column were compared with that on [PSOMIM][Cl] column. [PSOMIM][NTf₂] stationary phase also exerted good selectivity for fatty acid methyl esters (FAMEs), polychlorinated biphenyls (PCBs) and aromatic amines.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Elution Process