Related Experiment Video
Updated: Jun 5, 2026

06:51
Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
Evaluation of the precision of three implant transfer impression techniques using two elastomeric impression
Tamer Mohamed Nasr Mostafa1, Mohamed Nabeel Mohamed Elgendy, Nahed Ahmed Kashef
1Department of Prosthodontics, Faculty of Dentistry, Tanta University, El-Geish Street, Tanta, Egypt. nasr_tifour@yahoo.com
The International Journal of Prosthodontics
|January 7, 2011
Summary
For completely edentulous mandibles, direct implant impression techniques (splinted or unsplinted) yield accurate linear distances. The indirect technique showed significant differences, but impression materials did not affect accuracy.
Area of Science:
- Dental Implantology
- Prosthodontics
- Materials Science in Dentistry
Background:
- Accurate fabrication of definitive casts is crucial for successful implant-supported prostheses.
- The edentulous mandible presents unique challenges for impression techniques.
- Evaluating different impression techniques and materials is essential for optimizing clinical outcomes.
Purpose of the Study:
- To compare the accuracy of linear implant distances using various impression techniques and materials.
- To assess the influence of direct splinted, direct unsplinted, and indirect impression methods on cast accuracy.
- To determine if different impression materials impact the precision of definitive casts for edentulous mandibles.
Main Methods:
- A master cast with four anterior interforaminal implants was created in polyurethane resin.
- Six technique-material combinations were used for impressions.
- Ten definitive casts were produced per technique, and linear implant distances were measured using a traveling microscope.
Main Results:
- No statistically significant difference in accuracy was found between direct unsplinted and direct splinted impression techniques (P > .05).
- The indirect impression technique resulted in statistically significant differences compared to direct methods (P < .05).
- No statistically significant difference was observed between the two impression materials evaluated.
Conclusions:
- Direct impression techniques, both splinted and unsplinted, provide comparable and accurate linear measurements for implants in the edentulous mandible.
- The indirect impression technique is less accurate for determining inter-implant distances in this context.
- Impression material choice does not significantly affect the accuracy of definitive casts in this study.