Related Experiment Video
Updated: Jun 5, 2026

Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
[Anatomical considerations for the placement of C₂ spinous process screws]
Guan-yi Liu1, Rong-ming Xu, Wei-hu Ma
1Department of Orthopaedics, Ningbo Sixth People's Hospital, Ningbo 315040, China.
Objectives:
To quantitatively anatomically evaluate the C₂ spinous process, analyze the anatomical feasibility of the C₂ spinous process screws and its clinical significance.
Methods:
To dissect and evaluate 30 cervical cadaveric spines of C₂ which were taken to expose the lamina and spinous process. Anatomic quantitative evaluation of the C₂ spinous process included its height and width. Twenty cervical cadaveric spines of C₂ were chosen to the study of the placement of the C₂ spinous process screws. The starting point for the C₂ spinous process screw insertion was located at the base of the spinous process. After the entrance point of spinous process screws was determined, posterior C₂ spinous process screw implantation was performed bilaterally under direct visualization. On the morphologic CT scan, the width of C₂ spinous process base, the angle and length of the spinous process screw trajectory, and the distance between the tip of the screw and the spinal cord and the vertebral artery were measured.
Results:
The average height and width of the C₂ spinous process were (12.90 ± 1.30) mm and (18.86 ± 1.17) mm respectively. The C₂ spinous process screws were successfully placed without impingement the spinal cord or the vertebral artery and the breakage of the spinous process. On the CT scan, the average width of the base of C₂ spinous process was (20.7 ± 1.3) mm. The placed angles of the screws were 1.8° ± 1.0° in the axial plane. The distance between the tip of the screw and the spinal cord or the vertebral artery was (8.3 ± 2.6) mm and (20.2 ± 3.1) mm respectively. There were little differences between superior and inferior screws in the angle, the distance between the tip of the screw and the spinal cord or the vertebral artery, but without significance (P > 0.05). The average trajectory length of the C₂ spinous process screws was (19.7 ± 1.1) mm. The average trajectory length of the superior spinous process screws was shorter than that of inferior spinous process screws, with great differences (t = 3.566, P < 0.01).
Conclusions:
There is the anatomic feasibility of the C₂ spinous process screw fixation which may afford an alternative to standard screw placement for axis fixation. The biomechanical study for the C₂ spinous process screw is also necessary.
Related Concept Videos
General Structure of a Vertebra
Cranial Bones: Superior and Posterior View
The frontal bone is the single bone that forms the forehead. At its anterior midline, between the eyebrows, there is a slight depression called the glabella. The frontal bone also forms the supraorbital margin of the orbit. Near the middle of this margin is the supraorbital foramen, the opening that provides passage for a sensory nerve to the forehead. The frontal bone is thickened just above each supraorbital margin,...
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form the...
Articulations of the Vertebral Column