Related Experiment Video
Updated: Jun 5, 2026

Structure and Coordination Determination of Peptide-metal Complexes Using 1D and 2D 1H NMR
Published on: December 16, 2013
Dependence on effective saturation of numbers of singlet peaks in one- and two-dimensional separations
1Department of Chemistry and Biochemistry, Southern Illinois University at Carbondale, Carbondale, IL 62901, USA. chimicajmd@ec.rr.com
Abstract:
The average numbers of singlet peaks in one-dimensional (1D) and two-dimensional (2D) separations of randomly distributed peaks are predicted by statistical-overlap theory and compared against the effective saturation. The effective saturation is a recently introduced metric of peak crowding that is more practitioner-friendly than the usual metric, the saturation. The effective saturation absorbs the average minimum resolution of statistical-overlap theory, facilitating the comparison of 1D and 2D separations by traditional metrics of resolution and peak capacity. In this paper, singlet peaks are identified with maxima produced by a single mixture constituent. Their effective saturations are calculated from published equations for the average minimum resolution of 1D singlet peaks, and from equations derived here for the average minimum resolution of 2D singlet peaks. The fractions of peaks that are singlets in 1D and 2D separations are predicted by statistical-overlap theory as functions of saturation but are compared as functions of effective saturation. The two fractions differ by no more than 0.033 at any effective saturation between 0 and 6, when the distribution of peak heights is exponential and the edge effect is neglected. This result shows that 1D and 2D separations of randomly distributed peaks are about the same in their ability to separate singlet peaks as maxima, when assessed relative to effective saturation. Empirical equations in effective saturation are reported for the fractions of peaks that are singlets. It is argued that the effective saturation is a good metric for comparing separations having different average minimum resolutions.
More Related Videos
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.