Dependence on effective saturation of numbers of singlet peaks in one- and two-dimensional separations

Joe M Davis1

  • 1Department of Chemistry and Biochemistry, Southern Illinois University at Carbondale, Carbondale, IL 62901, USA. chimicajmd@ec.rr.com

Talanta
|January 11, 2011
PubMed

Related Concept Videos

¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
¹H NMR: Complex Splitting01:13

¹H NMR: Complex Splitting

A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.