Related Experiment Video
Updated: Jun 5, 2026

Biochemical and Structural Characterization of the Carbohydrate Transport Substrate-binding-protein SP0092
Published on: October 2, 2017
Data requirements for the reliable use of atomic pair distribution functions in amorphous pharmaceutical
Timur Dykhne1, Ryan Taylor, Alastair Florence
1Department of Applied Physics and Applied Mathematics, Columbia University, 500 W. 120th St., Room 200 Mudd, MC 4701, New York, New York 10027, USA. td2218@columbia.edu
Purpose:
To determine the optimal measurement strategy for fingerprinting condensed phases of pharmaceutical systems using atomic pair distribution functions (PDFs) obtained from data collected using several types of x-ray diffraction instruments.
Methods:
PDFs of crystalline and amorphous-phase molecular systems derived from data accessible to copper-, molybdenum-, and silver-anode laboratory sources were compared to one another and synchrotron data using qualitative and quantitative methods.
Results:
We find that reliable fingerprinting is still possible using silver and molybdenum laboratory sources, but data from copper anode laboratory sources are unreliable for fingerprinting, yielding ambiguous and potentially incorrect results.
Conclusion:
The ambiguities make data measured using low energy x-rays unsuitable for fingerprinting active pharmaceutical ingredients and small molecule systems, and, in general, copper anode diffractometers are undesirable for this purpose; however, laboratory x-ray sources with either Mo or Ag anodes are well suited for this application.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
11:27A Package of Established Analytical Tools to Investigate the Solid-State Alteration of Lipid-Based Excipients
Published on: August 9, 2022
Related Concept Videos
Drug Dissolution: Requirements and Profile Comparison
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence