Using pulse oximetry to account for high and low frequency physiological artifacts in the BOLD signal
Timothy D Verstynen1, Vibhas Deshpande
1Keck Center for Integrative Neuroscience, University of California, San Francisco, San Francisco, CA, USA. timothyv@pitt.edu
Abstract:
The BOLD signal not only reflects changes in local neural activity, but also exhibits variability from physiological processes like cardiac rhythms and breathing. We investigated how both of these physiological sources are reflected in the pulse oximetry (PO) signal, a direct measure of blood oxygenation, and how this information can be used to account for different types of noise in the BOLD response. Measures of heart rate, respiration and PO were simultaneously recorded while neurologically healthy participants performed an eye-movement task in a 3T MRI. PO exhibited power in frequencies that matched those found in the independently recorded cardiac and respiration signals. Using the phasic and aphasic properties of these signals as nuisance regressors, we found that the different frequency components of the PO signal could be used to identify different types of physiological artifacts in the BOLD response. A comparison of different physiological noise models found that a simple, down-sampled version of the PO signal improves the estimation of task-relevant statistics nearly as well as more established noise models that may run the risk of over-parameterization. These findings suggest that the PO signal captures multiple sources of physiological noise in the BOLD response and provides a simple and efficient way of modeling these noise sources in subsequent analysis.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Pulse
The pulse serves as a clinical indicator...