Determination of Trace Amounts of Lead Using the Flotation-spectrophotometric method
Sabah Shiri1, Ali Delpisheh, Ali Haeri
1Department of Chemistry, Payame Noor University of Ilam, Iran.
Abstract:
The present study describes a simple and highly selective method for separation, preconcentration and spectrophotometric determination of extremely low concentrations of lead. It is based on flotation of a complex of Pb(2+) ions and Alizarin yellow between aqueous and n-hexane interface at pH = 6. The proposed procedure is also applied for determination of lead in both tap water and prepared sea water samples. Beer's Law was obeyed over the concentration range of 3.86 × 10(-8) To 8.20 × 10(-7) molL(-1) (8-170 ngmL(-1)) with an apparent molar absorptivity of 1.33 × 10(6) molL(-1) cm(-1) for a 100 mL aliquot of the water sample. The detection limit (n = 10) was 8.7 × 10(-9) molL(-1) (1.0 ngmL(-1)) and the Relative standard deviation (R.S.D), (n = 10) for 7.2 × 10(-7) molL(-1) (150 ngmL(-1)) of Pb (II) was 4.36%. A notable advantage of the method is that the determination of Pb (II) is free from the interference of almost all cations and ions found in the environment and waste water samples. The determination of Pb (II) in tap and synthetic seawater samples was also carried out by the present method. The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Flame Photometry: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Washing, Drying, and Ignition of Precipitates
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...