Related Experiment Video
Updated: Jun 5, 2026

A Protocol for Detecting and Scavenging Gas-phase Free Radicals in Mainstream Cigarette Smoke
Published on: January 2, 2012
Direct determination of hydrogen cyanide in cigarette mainstream smoke by ion chromatography with pulsed amperometric
Zi-Wei Zhang1, Ying-Bo Xu, Cheng-Hui Wang
1Department of Chemistry, University of Science and Technology of China, Hefei 230026, China.
Abstract:
The determination of hydrogen cyanide in cigarette mainstream smoke has been achieved by ion chromatography (IC) with pulsed amperometric detection (PAD). The proposed method of totally trapping whole cigarette mainstream smoke by Cambridge filters, which are treated with sodium hydroxide/ethanol solution, possesses the advantage of fast analysis time over the widespread used solution absorption method. The possible co-existing interferents are evaluated under the optimized detection conditions and excellent recoveries of cyanide are obtained. The cyanide content of absorption solution can be directly determined by the optimized IC-PAD method without any pretreatments. The linear range is 0.0147-2.45 μg/mL with R² value of 0.9997. The limit of the detection is 3 μg/L for a 25 μL injection loop. The overall relative standard deviation of the method is less than 5.20% and the recovery range from 94.3% to 101.0%. The results obtained from the developed method are in good agreement with that of continuous flow analyzer (CFA) method.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
11:38High Content Screening Analysis to Evaluate the Toxicological Effects of Harmful and Potentially Harmful Constituents (HPHC)
Published on: May 10, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...