Related Experiment Video
Updated: Jun 5, 2026

Rotating the Intraocular Lens to Prevent Posterior Capsular Opacification in Cataract Surgeries
Published on: July 7, 2023
Alleviating debilitating photophobia and secondary exotropia caused by increased straylight by widening a small
Ruth Lapid-Gortzak1, Ivanka J E van der Meulen, Carla P Nieuwendaal
1Retina Total Eye Care, Driebergen, The Netherlands. r.lapid@amc.nl
Abstract:
In a patient with complaints of photophobia and an ocular deviation, straylight was found to be increased to 1.61 (log[s]), which is 5 times the normal value. The only relative clinical finding was the edge of a too small posterior capsulotomy. Visual acuity was normal. Six weeks after the posterior capsulotomy was widened to a diameter of 6.0 mm with a neodymium:YAG laser, the symptoms were resolved and the patient was satisfied. Straylight may manifest clinically as complaints of photophobia. Straylight increase, which can be related to slitlamp findings, may lead to an interventional decision. Our clinical decision-making was also guided by straylight measurements and proved to be crucial in resolving the patient's complaints. More study of clinical situations in which straylight measurement can be used is needed.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Photoreceptors and Visual Pathways
Focusing of Light in the Eye
Glaucoma: Overview