Comparison of four analytical techniques based on atomic spectrometry for the determination of total tin in canned foodstuffs
Related Experiment Video
Updated: Jun 5, 2026

Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
K Boutakhrit1, M Crisci, F Bolle
1Scientific Institute of Public Health, Section of Food, B-1050 Brussels, Belgium. Khalid.Boutakhrit@wiv-isp.be
Abstract:
Different techniques for the determination of total tin in beverages and canned foods by atomic spectrometry were compared. The performance characteristics of inductively coupled plasma-mass spectrometry (ICP-MS), hydride generation-inductively coupled plasma-atomic emission spectrometry (HG-ICP-AES), electrothermal atomisation-atomic absorption spectrometry (ETA-AAS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) were determined in terms of linearity, precision, recovery, limit of detection, decision limit (CCα) and detection capability (CCβ) (Decision 2002/657/EC). Calibration ranges were covered from ng l⁻¹ to mg l⁻¹ level. Limits of detection that ranged from 0.01, 0.05, 2.0 to 200 µg l⁻¹ were reached for ICP-MS; HG-ICP-AES; ETA-AAS and ICP-AES, respectively. Precision, calculated according to ISO 5725-2 for repeatability and within-laboratory reproducibility and expressed as relative standard deviation (RSD), ranged from 1.6% to 4.9%; and recovery, based on Decision 2002/657/EC, was found to be between 95% and 110%. Procedures for the mineralisation or extraction of total tin were compared. Wet digestion, sequentially, with nitric acid and hydrogen peroxide provided the best results. The influence of possible interferences present in canned food and beverage was studied, but no interference in the determination of tin was observed. Since maximum levels for tin established by European Union legislation vary from 50 mg kg⁻¹ in canned baby foods and infant foods up to 200 mg kg⁻¹ in canned food, ICP-AES was chosen as the preferred technique for routine analysis thanks to its good precision, reliability and ease of use. The accuracy of this routine method was confirmed by participation in six proficiency test schemes with z-scores ranging from -1.9 to 0.6. Several canned foodstuffs and beverage samples from a local market were analysed with this technique.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Lab
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Tandem Mass Spectrometry
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Atomic Absorption Spectroscopy: Atomization Methods