Objective:
To assess the feasibility of kissing second-generation drug-eluting balloons (DEB), which have better mechanical properties than the first-generation DEB, in order to optimize provisional bare-metal stenting (BMS) when treating coronary bifurcation lesions in patients with contraindication to drug-eluting stents.
Methods:
Consecutive patients with anticipated low compliance to dual antiplatelet therapy who are undergoing provisional stenting with an open-cell design BMS and final kissing balloon with second-generation DEB were enrolled in this feasibility study. Angiographic success and procedural success (i.e., angiographic success in absence of in hospital major cardiovascular events) were registered. Clinical follow-up was also attempted in all patients.
Results:
A total of 14 patients (mean age 66±9 years, nine men) participated on the study. The DEB used were SeQuent Please (B. Braun Melsungen, Berlin, Germany) in six patients, In.Pact Falcon (Medtronic Invatec, Roncadelle, Italy) in four patients, New Dior (Eurocor, Bonn, Germany) in two patients and Pantera Lux (Biotronik, Berlin, Germany) in another two patients. All procedures, but one, were performed by transradial access through a 6-French high-flow guiding catheter. True bifurcation was present in 50% of the patients. Angiographic and procedural success was obtained in all patients. At a mean follow-up of 234±81 days, all contacted patients were asymptomatic and free from major adverse cardiac events (including cardiac death, nonfatal myocardial infarction and target bifurcation revascularization).
Conclusion:
At the advent of dedicated bifurcation stents, kissing DEB appears safe and effective and can be used to implement innovative, simpler, safer and possibly more effective bifurcation techniques. These remarkable results have laid the ground for an ongoing prospective registry of the kissing DEB technique (KISSING DEBBIE study, ClinicalTrials.gov NCT01009996).
Related Concept Videos
Intrauterine Drug Delivery Systems
Drug Delivery: Enteral Route
Drugs in...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Oral Drug Delivery Systems: Continuous-Release Systems
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs through the...