Manual and computerized measurement of sagittal vertebral inclination in computed tomography images
Tomaž Vrtovec1, Boštjan Likar, Franjo Pernuš
1University of Ljubljana, Faculty of Electrical Engineering, Laboratory of Imaging Technologies, Slovenia. tomaz.vrtovec@fe.uni-lj.si
Study Design:
Sagittal vertebral inclination (SVI) was systematically evaluated in computed tomography (CT) images by three observers using six manuals and two computerized measurements.
Objective:
To analyze and compare manual and computerized measurements of SVI in CT images.
Summary Of Background Data:
A number of methods were proposed to measure SVI in lateral radiographic projections in the form of spinal curvature or segmental angulation. A systematic analysis of the manual and computerized measurements in sagittal CT cross-sections has not been performed yet.
Methods:
SVI was measured in CT images for 28 vertebrae independently by three observers. Manual measurements were obtained in sagittal cross-sections by manually identifying the vertebral body corners, which defined the lines of SVI (superior and inferior tangents, anterior and posterior tangents, mid-endplate and mid-wall lines) against reference horizontal or vertical lines. Computerized measurements were obtained by manually identifying the vertebral centroids, which initialized the automated method that evaluated SVI by searching for the planes of maximal symmetry of vertebral bodies in two dimensions and in three dimensions.
Results:
The midwall lines proved to be the most reproducible and reliable manual measurements (1.0° and 1.4° standard deviations [SD]). The computerized measurements in three dimensions were more reproducible and reliable (0.9° and 1.3° SD) and also most consistent with the midwall lines (2.1° SD and 1.7° mean absolute difference).
Conclusions:
The manual measurements based on mid-wall lines and the computerized measurements in three dimensions yielded the lowest intraobserver and interobserver variability of SVI. However, in terms of speed and operator friendliness, the computerized measurements may represent an adequate alternative to manual measurements.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...