Related Experiment Video
Updated: Jun 4, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
What blood temperature for an ex vivo extracorporeal circuit?
Thomas Rimmelé1, Jeffrey Bishop, Peter Simon
1The CRISMA (Clinical Research, Investigation, and Systems Modeling of Acute Illness) Laboratory, Department of Critical Care Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
Abstract:
Ex vivo circuits are commonly used to evaluate biomaterials or devices used for extracorporeal blood purification. However, various aspects of the ex vivo circuit, apart from the circuit materials, may affect inflammation and coagulation. One such aspect is temperature. The aim of this study was to evaluate the influence of different blood temperature conditions on inflammation parameters in an ex vivo circuit. Blood was collected from 20 healthy volunteers and run through three different experimental conditions for 4 h: a miniaturized ex vivo extracorporeal circuit equipped with a blood warmer set to 37°C, the same circuit without the warmer (23°C), and a tube placed in an incubator at 37°C (no circuit). We measured the granulocyte macrophage colony-stimulating factor, the tumor necrosis factor, and the interleukin (IL)-1β, IL-6, IL-8, and IL-10 concentrations at baseline, 15, 60, 120, and 240 min. Human leukocyte antigen (HLA)-DR, CD11b, CD11a, CD62L, tumor necrosis factor alpha converting enzyme, annexin V expression, and NFkB DNA binding were measured in monocytes and polymorphonuclear neutrophils (PMNs) using flow cytometry at baseline, 120 min, and 240 min. While cytokine production over time was very slight at room temperature, levels increased by more than 100-fold in the two heated conditions. Differences in the expression of some surface markers were also observed between the room temperature circuit and the two heated conditions (CD11b PMN, P < 0.0001; HLA-DR Mono, P=0.0019; and CD11a PMN, P<0.0001). Evolution of annexin V expression was also different over time between the three groups (P=0.0178 for monocytes and P=0.0011 for PMNs). A trend for a greater NFkB DNA binding was observed in the heated conditions. Thus, for ex vivo studies using extracorporeal circuits, heating blood to maintain body temperature results in significant activation of inflammatory cells while hypothermia (room temperature) seems to suppress the leukocyte response. Both strategies may lead to erroneous conclusions, possibly masking some specific effects of the device being studied. Investigators in this field must be aware of the fact that blood temperature is a crucial confounding parameter and the type of "background noise" they will face depending on the strategy adopted.
Related Concept Videos
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C (97–99°F), remaining relatively stable...
Body Temperature
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...