2D-HPLC-MS Technology Combined with Molecular Network for the Identification of Components in Tibetan Medicine Aconitum pendulum
Published on: December 8, 2023
[Simultaneously determination of atropine sulphate, diphenhydramine hydrochloride, capsaicin and dihydrocapsaicin in
Xiaobin Jia1, Qi Liu, Yingjie Wei
1Key Laboratory of New Drug Delivery System of Chinese Meteria Medica, Jiangsu Provincial Academy of Chinese Medicine, Nanjing 210028, China. jxiaobin2005@hotmail.com
Objective:
To establish RP-HPLC method for determination of atropine sulphate, diphenhydramine hydrochloride, capsaicin and dihydrocapsaicin in pain-relieving plaster for arthritis.
Method:
The sample were separated on an Alltima C18 Column (4.6 mm x 250 mm, 5 microm) with the moblie phase of CH3 CN-0.1% H3 PO4. Flow rate was 1 mL x min(-1). The detective wavelength was set at 210 and 280 nm. Column temperature was 30 degrees C.
Result:
The calibration curve for atropine sulphate, diphenhydramine hydrochloride, capsaicin and dihydrocapsaicin revealed linearity in the range of 2.01-50.25, 15.08-377.00, 5.02-125.50, 5.03-125.75 mg x L(-1), respectively. The recoveries of atropine sulphate, diphenhydramine hydrochloride, capsaicin and dihydrocapsaicin were 99.00% with RSD of 0.95%, 99.89% with RSD of 1.2%, 100.1% with RSD of 1.5% and 99.51%, with RSD of 1.4%, respectively.
Conclusion:
The method is simple, rapid and accurate, which is suitable for the quality control of pain-relieving plaster for arthritis.