Toric intraocular lens misalignment inducing astigmatism after refractive surgery
Adriana S Forseto1, Ricardo M Nosé, Walton Nosé
1Eye Clinic Day Hospital, Metropolitan University of Santos, Sao Paulo, Brazil. forseto@uol.com.br
Journal of Refractive Surgery (Thorofare, N.J. : 1995)
|February 18, 2011
Summary
Unexpected astigmatism occurred after cataract surgery with toric lens implantation in a patient with prior corneal refractive surgery. Careful corneal topography analysis is crucial for accurate toric intraocular lens alignment.
Area of Science:
- Ophthalmology
- Refractive Surgery
- Corneal Surgery
Background:
- Cataract surgery with toric intraocular lens (IOL) implantation is a common procedure to correct refractive errors.
- Previous corneal refractive surgery can alter corneal topography, potentially complicating IOL calculations and alignment.
Observation:
- A 46-year-old male with bilateral cataracts and prior photorefractive keratectomy (PRK) underwent phacoemulsification and toric IOL implantation.
- The operated eye developed unexpected astigmatism despite apparent proper IOL alignment based on preoperative simulated keratometry (K) values.
Findings:
- Retrospective analysis revealed a mismatch in the steepest corneal meridian, causing an off-axis IOL.
- Secondary rotation of the toric IOL successfully improved uncorrected and corrected distance visual acuity.
Implications:
- Accurate assessment of corneal topography is essential for toric IOL alignment in patients with a history of corneal refractive surgery.
- This case highlights the importance of qualitative topographic analysis to identify the true steepest corneal meridian and ensure optimal refractive outcomes.
Related Concept Videos
Focusing of Light in the Eye
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Angle Closure Glaucoma: Treatment
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
Glaucoma: Overview
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
Open Angle Glaucoma: Treatment
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...