Related Experiment Video
Updated: Jun 4, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Kinetic investigation of the relationship between the efficiency of columns and their diameter
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
Many brands of packing materials made of fine particles are now available in both conventional (4.6 mm i.d.) and narrow-bore (2.1 mm i.d.) columns. It is a general observation that the efficiency of the former tends to be markedly higher than that of the latter. This report provides a detailed illustration of the characteristics of this enigma. The corrected reduced plate heights of three brands of columns packed with shell particles in 4.6 and 2.1 mm I.D. columns were measured. The brands were the 1.7 and 2.6 μm Kinetex-C(18) (Phenomenex, Torrance, CA, USA), the 2.7 μm Poroshell120-C(18) (Agilent Technologies, New Castle, DE, USA), and the 2.7 μm Halo-C(18) (Advanced Material Technologies, Wilmington, DE, USA). The extra-column contributions were minimized by optimizing the configuration of the instrument (injection volume <1.0 μL, 115 μm needle seat capillary, 80 μm connecting tubes, no heat exchanger, 0.8 μL detection cell). The correct peak variances were derived from the numerical integration of the first and second order moments of the experimental band profiles. These experimental results confirm that the kinetic performance of narrow-bore columns is inferior to that of conventional columns for all three brands of shell particles. We demonstrate that this difference is accounted for by a contribution to the column HETP of the long-range eddy diffusion term that is larger in the 2.1 than in the 4.6 mm I.D. columns. While the associated relative velocity biases are of comparable magnitude in both types of columns, the characteristic radial diffusion lengths are of the order of 100 and 40 μm in the wall regions of narrow-bore and conventional columns, respectively.
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Euler's Formula to Columns with Other End Conditions
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating within the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...

