Comprehensive two-dimensional gas chromatography to characterize hydrocarbon mixtures in lithic materials
M Olivares1, M Irazola, A Vallejo
1University of the Basque Country, Department of Analytical Chemistry, P.O. Box 644 E-48080, Bilbao, Basque Country, Spain.
Abstract:
The analysis of organic biomarkers in chert samples offers key information about the environmental conditions in which these samples were formed, and this information can be used to track the lithic materials of many archaeological artifacts. Since the content of the organic fraction is very low and the complexity of the organic extracts is quite high, we have optimized the GC×GC separation of these mixtures. Making use of mixture of C(16)H(34)-C(44)H(90)n-alkane standards, a central composite design was carried out taking into account the carrier flow in the first and second columns, the modulation period and the discharge time. Regarding the measured responses, though the initially considered one was the peak volume, we have also evaluated the effects on the number of modulated peaks per analyte, the symmetry of the modulated peaks and the number of detected compounds. The final optimum conditions were defined as follows: a hydrogen flow of 1.2 mL/min in the first column and 18 mL/min in the second one, a modulation period of 1.4 s and a discharge time of 0.1 s and under these conditions all the response variables showed optimum values. Based on this optimized method several chert samples obtained from different stratigraphic levels in an ancient quarry were studied and we were able to distinguish them on the basis of the different constituents of organic biomarkers, such as mono-methylated alkanes, cyclic n-alkanes, branched alkanes, steranes and hopanes.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...