Estimation of radiation exposure of different dose saving techniques in 128-slice computed tomography coronary
Dominik Ketelsen1, Michael Fenchel, Markus Buchgeister
1Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany. dominik.ketelsen@med.uni-tuebingen.de
Purpose:
To estimate the effective dose of cardiac CT with different dose saving strategies dependent on varying heart rates.
Materials And Methods:
For dose measurements, an Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a 128-slice single source scanner providing a rotation time of 0.30s and standard protocols with 120 kV and 160 mAs/rot. Protocols were evaluated without ECG-pulsing, with two different ECG-pulsing techniques, and automated exposure control with a simulated heart rate of 60 and 100 beats per minute.
Results:
Depending on different dose saving techniques and heart rate, the effective whole-body dose of a cardiac scan ranged from 2.8 to 9.5 mSv and from 4.3 to 16.0 mSv for males and females, respectively. The radiation-sensitive breast tissue in the primary scan range results in an increased female dose of 66.7 ± 6.0%. Prospective triggering has the greatest potential to reduce the effective dose to 27.8%, compared to a comparable scan protocol with retrospective ECG-triggering with no ECG-pulsing. Furthermore, the heart rate influences the radiation exposure by increasing significantly at lower heart rates.
Conclusion:
Due to this broad variability in radiation exposure of a cardiac CT, the radiologist and the CT technician should be aware of the different dose reduction strategies.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography