1Canadian Light Source Inc., 101 Perimeter Road, Saskatoon, Saskatchewan, Canada S7N 0X4.
Abstract:
Vibration is often a problem causing poor quality of photon beams at synchrotron radiation facilities, since beamlines are quite sensitive to vibrations. Therefore, vibration analysis and control at synchrotron radiation facilities is crucial. This paper presents investigations on mechanical vibrations at four beamlines and endstations at the Canadian Light Source, i.e. the Canadian Macromolecular Crystallography Facility 08ID-1 beamline, the Hard X-ray MicroAnalysis 06ID-1 beamline, the Resonant Elastic and Inelastic Soft X-ray Scattering 10ID-2 beamline, and the Scanning Transmission X-ray Microscope endstation at the Spectromicroscopy 10ID-1 beamline. This study identifies vibration sources and investigates the influence of mechanical vibrations on beamline performance. The results show that vibrations caused by movable mechanical equipment significantly affect the data acquired from beamlines.