Related Experiment Video
Updated: Jun 4, 2026

Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Physical signal modulation of time-of-flight mass analyzers increases precision and decreases noise
Jonathan K Hilmer1, Brian Bothner
1Chemistry and Biochemistry, Montana State University, Bozeman, MT 59717, USA.
Abstract:
Recently, an increased emphasis has been placed on the ability to make mass measurements with high accuracy and precision. The motivation for this is that high-precision mass measurements, together with isotope intensity matching, permit confirmation of molecular formulas and de novo molecular formula prediction, both of which enhance the value of proteomics and metabolomics data. The confidence of mass-based conclusions also depends on reliable estimates of uncertainty. However, determining the precision of a particular measurement remains a complicated process. For signals which are well-resolved and of sufficient intensity, an often-overlooked factor for high precision is the mass sampling frequency (abscissa, Δx). We have analyzed the impact of Δx on the centroid calculation of peak position, and find that existing quality standards, such as 4 or 5 samples per peak, may not be sufficient to achieve high precision. Time-domain and m/z-domain sampling frequency on time-of-flight (TOF) mass analyzers can be improved using a new method that we call Physical Signal Modulation (PSM). PSM allows very substantial improvements by decreasing Δx without requiring specialized hardware or digitizers. In addition to providing accuracy improvements, PSM also dramatically improves signal-to-noise ratios by removing coherent noise. Software to perform PSM data processing is available as part of the PySpecTools package.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
Mass Analyzers: Common Types
Mass Analyzers: Overview
Tandem Mass Spectrometry
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
MALDI-TOF Mass Spectrometry
Mass Spectrometers