Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology01:28

Three-Dimensional Microscopy in Microbiology

Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
Two-Dimensional Microscopy in Microbiology01:29

Two-Dimensional Microscopy in Microbiology

Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Radiomic MRI model for predicting the development of worrisome features in branch-duct intraductal papillary mucinous neoplasms (BD-IPMNs).

La Radiologia medica·2026
Same author

Explainable deep-learning detection of microplastic fibers via polarization-resolved holographic microscopy.

Optics express·2026
Same author

Teaching parathyroid-sparing thyroidectomy: Clinical and educational impact of near-infrared autofluorescence. Results of a retrospective case-control study.

Surgery·2026
Same author

Advances in Digital Holography, 3-D Imaging, and Optical Information Processing: introduction.

Biomedical optics express·2026
Same author

Prognostic factors and survival after recurrence in major salivary gland carcinomas: a multicenter study.

Oral oncology·2026
Same author

CD44+ and CD133+ Extracellular Vesicles as Future Potential Targets in Gastrointestinal Tumor.

Frontiers in bioscience (Landmark edition)·2026
Same journal

Generalizable framework for multi-site bone density prediction using non-dominant wrist optical biomarkers.

Biomedical optics express·2026
Same journal

Erratum: Review of dynamic optical coherence tomography for intracellular motility [Invited]: errata.

Biomedical optics express·2026
Same journal

Digital-micromirror-device-based illumination strategies for background suppression in single-molecule localization microscopy.

Biomedical optics express·2026
Same journal

Synergistic combination of convective self-assembly and hollow core fiber for sensitive SERS detection of glucose molecules.

Biomedical optics express·2026
Same journal

Multimodal diagnostic network integrating infrared and mass spectra for lung cancer.

Biomedical optics express·2026
Same journal

Multimodal Optical Biosensing for Precision Medicine and Healthcare: Introduction to the feature issue.

Biomedical optics express·2026
See all related articles

Related Experiment Video

Updated: Jun 4, 2026

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

Dynamic DIC by digital holography microscopy for enhancing phase-contrast visualization.

Lisa Miccio, Andrea Finizio, Roberto Puglisi

    Biomedical Optics Express
    |February 23, 2011
    PubMed
    Summary
    This summary is machine-generated.

    Dynamical Differential Holographic Image Contrast (DDHIC) uses digital holography to create phase-contrast images of dynamic biological samples. This method simplifies setups and allows for post-acquisition optimization of image contrast.

    Keywords:
    (090.1995) Digital holography(100.2980) Image enhancement(180.3170) Interference microscopy

    More Related Videos

    Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
    10:16

    Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects

    Published on: February 8, 2014

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy (DHM)
    07:27

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy (DHM)

    Published on: November 1, 2017

    Related Experiment Videos

    Last Updated: Jun 4, 2026

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
    10:28

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

    Published on: July 5, 2016

    Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
    10:16

    Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects

    Published on: February 8, 2014

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy (DHM)
    07:27

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy (DHM)

    Published on: November 1, 2017

    Area of Science:

    • Optics and Imaging
    • Biophysics
    • Digital Holography

    Background:

    • Classical Differential Image Contrast (DIC) requires specialized optics and is unsuitable for dynamic samples.
    • Digital Holography (DH) offers numerical wavefront manipulation and focusing capabilities.

    Purpose of the Study:

    • To introduce Dynamical Differential Holographic Image Contrast (DDHIC) for improved phase-contrast imaging.
    • To enable dynamic visualization and post-acquisition optimization of DIC parameters for biological samples.

    Main Methods:

    • Implementing DDHIC by numerically managing wavefronts obtained through DH.
    • Utilizing a single holographic recording to set DIC parameters a posteriori.
    • Applying numerical focusing inherent to DH.

    Main Results:

    • DDHIC eliminates the need for complex setups and movable components.
    • The technique allows for dynamic phase-contrast visualization from a single recording.
    • Optimization of DIC parameters like shear and bias is facilitated for enhanced imaging.

    Conclusions:

    • DDHIC offers a versatile and simplified approach to phase-contrast imaging of dynamic biological samples.
    • The method improves visualization and aids in selecting optimal imaging parameters for bio-scientists.